Category: Oscilloscope and accessoriesDescription: Digital LeCroy MSO104MXs-B 1GHz 22Channel 5 null 16 null 8Bit Digital storage (DSO), Mixed signal (MSO)8652
-
Category: Oscilloscope and accessoriesDescription: PASS PROBE 10:1 500MHz 10M OHMS27121+$2824.903410+$2799.222525+$2786.382050+$2773.5415100+$2760.7011150+$2747.8606250+$2735.0201500+$2722.1796
-
Category: Oscilloscope and accessoriesDescription: PASS PROBE 10:1 500MHz 10M OHMS67401+$2278.989910+$2258.271825+$2247.912850+$2237.5537100+$2227.1947150+$2216.8356250+$2206.4766500+$2196.1175
-
Category: Oscilloscope and accessoriesDescription: Teledyne LeCroy Passive probe PP022 is a standard probe that comes with most oscilloscopes. They are also sold as individual items and as spare parts. PP022 (PP022-1 single pack, PP022-2 two pack) has a bandwidth of 500 MHz, an input capacitance of 10 pF, and a probe tip diameter of 2.5 mm. It is a typical passive probe that provides 10:1 attenuation and has a high resistance of 10 M Ω. Its high input resistance makes this passive probe the best choice for instruments used for low-frequency signals, as it minimizes the circuit load at these frequencies. These passive probes are designed to handle voltages of at least 400 V. PP022 can handle up to 500 V. The Teledyne LeCroy passive probe has an attenuation sensing pin, which can activate the oscilloscope to automatically scale the waveform proportionally without the need for operator input. ###Note that the PP022 passive probe is compatible with Teledyne LeCroy WaveSurfer MXs-B and MSO MXs-B, WaveRunner 6 Zi, and HRO 12 oscilloscopes. Using a suitable passive probe for an oscilloscope means that the probe will be correctly compensated across the entire bandwidth range. Otherwise, only low-frequency compensation will be applied. ###Grounding lead, rigid probe tip (installed), rigid probe tip (spare), short collar (installed), spring hook, fine adjustment tool, long collar, IC insulator (black, brown, blue, green, gray -1 piece per piece), tip insulator 2.5 mm, probe tip cover, BNC adapter 2.5 mm, rotating grounding lead, rotating grounding lead adapter, grounding spring, printed circuit board adapter, spring tip, color coded ring (yellow, red, green, blue -2 pieces per piece), # # # Passive oscilloscope probe # # Note: All products in this series are available for use with tools with permanent grounding wires.4179
-
Category: Oscilloscope and accessoriesDescription: Teledyne LeCroy Passive probe PP023 is a standard probe that comes with most oscilloscopes. They are also sold as individual items and as spare parts. PP023 (PP023-1 single pack, PP023-2 two pack) has a bandwidth of 500 MHz, an input capacitance of 10 pF, and a probe tip diameter of 2.5 mm. It is a typical passive probe that provides 10:1 attenuation and has a high resistance of 10 M Ω. Its high input resistance makes this passive probe the best choice for instruments used for low-frequency signals, as it minimizes the circuit load at these frequencies. These passive probes are designed to handle voltages of at least 400 V. PP023 can handle up to 500 V. The Teledyne LeCroy passive probe has attenuation sensing pins that can activate the oscilloscope to automatically scale waveforms proportionally without the need for operator input. ###Note that the PP023 passive probe is compatible with Teledyne LeCroy HDO6000/HDO6000-MS and HDO8000 oscilloscopes, as well as with the MDA800 motor driver analyzer. Using a suitable passive probe for an oscilloscope or analyzer means that the probe will be correctly compensated across the entire bandwidth range. Otherwise, only low-frequency compensation will be applied. ###Grounding lead, rigid probe tip (installed), rigid probe tip (spare), short collar (installed), spring hook, fine adjustment tool, long collar, IC insulator (black, brown, blue, green, gray -1 piece per piece), tip insulator 2.5 mm, probe tip cover, BNC adapter 2.5 mm, rotating grounding lead, rotating grounding lead adapter, grounding spring, printed circuit board adapter, spring tip, color coded ring (yellow, red, green, blue -2 pieces per piece), # # # Passive oscilloscope probe # # Note: All products in this series are available for use with tools with permanent grounding wires.84891+$2816.235410+$2790.633325+$2777.832250+$2765.0311100+$2752.2301150+$2739.4290250+$2726.6279500+$2713.8268
-
Category: Oscilloscope and accessoriesDescription: Teledyne LeCroy Passive probe PP026 is a standard probe that comes with most oscilloscopes. They are also sold as individual items and as spare parts. PP026 (PP026-1 single pack, PP026-2 two pack) has a bandwidth of 500 MHz, an input capacitance of 10 pF, and a probe tip diameter of 5 mm. It is a typical passive probe that provides 10:1 attenuation and has a high resistance of 10 M Ω. Its high input resistance makes this passive probe the best choice for instruments used for low-frequency signals, as it minimizes the circuit load at these frequencies. These passive probes are designed to handle voltages of at least 400 V. PP026 can handle up to 500 V. The Teledyne LeCroy passive probe has an attenuation sensing pin, which can activate the oscilloscope to automatically scale the waveform proportionally without the need for operator input. ###Note that the PP026 passive probe is compatible with Teledyne LeCroy HDO4000/HDO4000-MS, HDO6000/HDO6000-MS, and HDO8000 oscilloscopes, as well as with the MDA800 motor driver analyzer. Using a suitable passive probe for an oscilloscope or analyzer means that the probe will be correctly compensated across the entire bandwidth range. Otherwise, only low-frequency compensation will be applied. ###Comes with rigid probe tip (installed), rigid probe tip (spare), fine-tuning tool, spring hook, color coded rings (2 per piece in yellow, red, green, blue), grounding lead (with alligator clip), grounding spring, printed circuit board adapter, BNC adapter 5mm, spring tip, probe tip cover, IC insulator (x2), tip insulator # # #, passive oscilloscope probe # # # Note: All products in this series are provided for use with tools with permanent grounding wires.5664
-
Category: Oscilloscope and accessoriesDescription: PASS PROBE 10:1 500MHz 10M OHMS11661+$2757.839710+$2732.768425+$2720.232850+$2707.6972100+$2695.1615150+$2682.6259250+$2670.0903500+$2657.5546
-
Category: Oscilloscope and accessoriesDescription: Teledyne LeCroy Passive probe PP024 is a standard probe that comes with most oscilloscopes. They are also sold as individual items and as spare parts. PP024 (PP024-1 single pack, PP024-2 two pack) has a bandwidth of 500 MHz, an input capacitance of 10 pF, and a probe tip diameter of 5 mm. It is a typical passive probe that provides 10:1 attenuation and has a high resistance of 10 M Ω. Its high input resistance makes this passive probe the best choice for instruments used for low-frequency signals, as it minimizes the circuit load at these frequencies. These passive probes are designed to handle voltages of at least 400 V. PP024 can handle up to 500 V. The Teledyne LeCroy passive probe has an attenuation sensing pin, which can activate the oscilloscope to automatically scale the waveform proportionally without the need for operator input. ###Note that the PP024 passive probe is compatible with Teledyne LeCroy WaveSurfer MXs-B and MSO MXs-B, WaveRunner 6 Zi, and HRO 12 oscilloscopes. Using a suitable passive probe for an oscilloscope means that the probe will be correctly compensated across the entire bandwidth range. Otherwise, only low-frequency compensation will be applied. ###Comes with rigid probe tip (installed), rigid probe tip (spare), fine-tuning tool, spring hook, color coded rings (2 per piece in yellow, red, green, blue), grounding lead (with alligator clip), grounding spring, printed circuit board adapter, BNC adapter 5mm, spring tip, probe tip cover, IC insulator (x2), tip insulator # # #, passive oscilloscope probe # # # Note: All products in this series are provided for use with tools with permanent grounding wires.11591+$3541.884510+$3509.685625+$3493.586150+$3477.4866100+$3461.3871150+$3445.2877250+$3429.1882500+$3413.0887
-
Category: Oscilloscope and accessoriesDescription: Teledyne LeCroy Passive probe users do not need to input, LeCroy passive probe can automatically scale oscilloscope waveforms. They are optimized for maximum waveform fidelity, including high-frequency signal components, designed to be robust and suitable for daily use. ###Note that PP007-WR is designed for the WaveRunner 6000 series, while PP007-WS is designed for the WaveSurfer 400 series oscilloscope. The physical design of these two probes is the same. All connection attachments, standards, and options are suitable for both models. PP008-1 is suitable for use with WaveRunner Xi series oscilloscopes. ###Passive oscilloscope probe # # # Note provides all products in this series for use with tools with permanent grounding wires.64461+$3552.363110+$3520.068925+$3503.921850+$3487.7747100+$3471.6276150+$3455.4805250+$3439.3334500+$3423.1863
-
Category: Oscilloscope and accessoriesDescription: Teledyne LeCroy PPE The LeCroy PPE series of high-voltage passive probes are widely used in fields where high-voltage measurement must be safe and accurate. The new technology uses hybrid circuits to reduce noise and overshoot to provide precise response. The fixed attenuation standard probe can automatically readjust any LeCroy 9300C or LC series oscilloscope to appropriately attenuate the probe factor. ###Note probe ring: PPE1.2KV=No; PPE20KV, PPE2KV, PPE4KV, PPE5KV, PPE6KV=cable length: PPE20kv=3m; PPE1.2kV, PPE2kV, PPE4kV, PPE5kV, PPE6kV=2m PPE20KV peak voltage=40kV # # # High voltage oscilloscope probe2851
-
Category: Oscilloscope and accessoriesDescription: Teledyne LeCroy PPE The LeCroy PPE series of high-voltage passive probes are widely used in fields where high-voltage measurement must be safe and accurate. The new technology uses hybrid circuits to reduce noise and overshoot to provide precise response. The fixed attenuation standard probe can automatically readjust any LeCroy 9300C or LC series oscilloscope to appropriately attenuate the probe factor. ###Note probe ring: PPE1.2KV=No; PPE20KV, PPE2KV, PPE4KV, PPE5KV, PPE6KV=cable length: PPE20kv=3m; PPE1.2kV, PPE2kV, PPE4kV, PPE5kV, PPE6kV=2m PPE20KV peak voltage=40kV # # # High voltage oscilloscope probe63291+$5341.671510+$5293.110925+$5268.830550+$5244.5502100+$5220.2699150+$5195.9896250+$5171.7092500+$5147.4289
-
Category: Oscilloscope accessoriesDescription: Teledyne LeCroy The Teledyne LeCroy current probe can accurately and reliably measure AC, DC, and impulse pulse currents without disconnecting the circuit or inserting a shunt. This ability is based on the combination of Hall effect and transformer technology. Many current probes require external power supply devices or amplifiers to display waveforms on the oscilloscope screen. LeCroy current probe is powered by LeCroy ProBus ® Connector power supply, no additional hardware required. In addition to providing power, the ProBus connector also enables communication between the current probe and oscilloscope, automatically displaying the current waveform in amperes on the screen and correctly calculating the power recorded on the scale in watts. This integration also supports direct activation of demagnetization and auto zeroing functions from the oscilloscope by pressing a button. The applications of LeCroy current probes include the design and testing of switching power supply equipment, motor drives, electric vehicles, and uninterruptible power supply equipment. Rise time (typical)3089
-
Category: Oscilloscope and accessoriesDescription: Teledyne LeCroy One of the advantages of using Teledyne LeCroy instruments with passive high-voltage probes for DXC-5100 is that RS provides a large number of accessories for use with them. The Teledyne LeCroy passive high voltage probe for DXC-5100 is suitable for use with the Teledyne LeCroy differential amplifier DA1855A series (801-4852, 801-4861). To achieve full performance, it requires the Teledyne LeCroy passive attenuator DA101 (789-8150).9916
-
Category: Oscilloscope and accessoriesDescription: LeCroy WaveAce 1000 The 2000 series LeCroy WaveAce 1000 and 2000 models are small and affordable oscilloscopes that offer a powerful combination of properties, including long-term memory, color screen, extensive measurement capabilities, advanced triggering, and excellent connectivity, enhancing fault diagnosis and reducing debugging time. The 7-inch widescreen color display can display up to 5 measurement values, saving space. The measurement dashboard can simultaneously display 32 automatic measurement values and 5 mathematical functions for additional analysis (including addition, subtraction, multiplication, division, and FFT). FFT can be viewed through 4 windows and 2 vertical scales to obtain insightful insights into the frequency domain. Built in pass/fail mask testing can quickly identify problems and highlight large internal waveforms when problems occur, and set up USB connections for storage and remote control of printers, memory sticks, and PCs. Note: WaveAce soft carry case 724-0937 (WA-SOFTCASE) is provided separately. Comes with 10:1, 1:1 switchable passive probes (one per channel); Multi language user interface and assistance; WaveStudio comes with a USB cable; Introduction manual; Calibration and Performance Certificate # # # Teledyne LeCroy Digital Oscilloscope # # # LeCroy Digital Oscilloscope4313
-
Category: Oscilloscope and accessoriesDescription: LeCroy WaveAce 1000 The 2000 series LeCroy WaveAce 1000 and 2000 models are small and affordable oscilloscopes that offer a powerful combination of properties, including long-term memory, color screen, extensive measurement capabilities, advanced triggering, and excellent connectivity, enhancing fault diagnosis and reducing debugging time. The 7-inch widescreen color display can display up to 5 measurement values, saving space. The measurement dashboard can simultaneously display 32 automatic measurement values and 5 mathematical functions for additional analysis (including addition, subtraction, multiplication, division, and FFT). FFT can be viewed through 4 windows and 2 vertical scales to obtain insightful insights into the frequency domain. Built in pass/fail mask testing can quickly identify problems and highlight large internal waveforms when problems occur, and set up USB connections for storage and remote control of printers, memory sticks, and PCs. Note: WaveAce soft carry case 724-0937 (WA-SOFTCASE) is provided separately. Comes with 10:1, 1:1 switchable passive probes (one per channel); Multi language user interface and assistance; WaveStudio comes with a USB cable; Introduction manual; Calibration and Performance Certificate # # # Teledyne LeCroy Digital Oscilloscope # # # LeCroy Digital Oscilloscope3709
-
Category: Oscilloscope and accessoriesDescription: HDO4000 The HDO4000 model of high-definition oscilloscope provides precise measurement and fast debugging. They combine Teledyne LeCroy's HD4096 high-definition technology with long-term memory, compact exterior design, 12.1-inch WXGA multi touch display, and powerful debugging tools. The innovative rotating/tilting foot allows for easy access to four different viewing positions, achieving optimal flexibility during use. Teledyne LeCroy HD4096 high-definition technology with 12 bit ADC resolution and multilingual user interface. Intuitive and efficient touch screen interface (such as configuring channels, timing, and triggering operations). WaveScan advanced search and lookup (such as low waves and spikes). LabNotebook document and report generation (just press a button). History recording mode, waveform playback, spectrum analyzer mode. Note that the separately provided HDO4000 accessories include: passive probe PP026-1 or PP026-2 (922-5270 or 922-5273); Current probes CP030A (878-7604) and CP031A (878-7607); High voltage differential probes HVD3106-6M (878-7601), HVD3206-6M (918-6866); Active probe ZS1500 (878-7610); Active differential probes ZD500 (878-7613) and ZD1500 (878-7617); Trigger and decode options CAN FD (851-3191), ENET bus (878-7629); Manchester bus (878-7623), NRZ bus (878-7632), CAN LIN FlexRay package (878-7635), CAN (878-7639), LIN (878-7648), FlexRay (878-7641), SENT bus (878-7645), 12C SPI UART RS232 package (878-7654), 12C bus (878-7651), SPI bus (878-7663), UART RS232 bus (878-7679), AudioBus (878-7682), DigRF 3G bus (878-7689), DigRF V4 bus (878-7698), D-PHY bus (878-7695), ARINC 429 bus symbol (878-7708), MIL-STD-1553 (878-7695), USB 2.0 bus (878-7718), USB 2.0 HSIC (878-7724), power analysis (878-7749), spectrum analysis (878-7746). ###Comes with passive probe (1 per channel), beginner's guide, antivirus software (trial version), Microsoft Windows Embedded Standard 7 P 64 bit license, commercial NIST traceable calibration with certificate, power cable # # # Teledyne LeCroy HD oscillosco1060
-
Category: Oscilloscope and accessoriesDescription: HDO4000 The HDO4000 model of high-definition oscilloscope provides precise measurement and fast debugging. They combine Teledyne LeCroy's HD4096 high-definition technology with long-term memory, compact exterior design, 12.1-inch WXGA multi touch display, and powerful debugging tools. The innovative rotating/tilting foot allows for easy access to four different viewing positions, achieving optimal flexibility during use. Teledyne LeCroy HD4096 high-definition technology with 12 bit ADC resolution and multilingual user interface. Intuitive and efficient touch screen interface (such as configuring channels, timing, and triggering operations). WaveScan advanced search and lookup (such as low waves and spikes). LabNotebook document and report generation (just press a button). History recording mode, waveform playback, spectrum analyzer mode. Note that the separately provided HDO4000 accessories include: passive probe PP026-1 or PP026-2 (922-5270 or 922-5273); Current probes CP030A (878-7604) and CP031A (878-7607); High voltage differential probes HVD3106-6M (878-7601), HVD3206-6M (918-6866); Active probe ZS1500 (878-7610); Active differential probes ZD500 (878-7613) and ZD1500 (878-7617); Trigger and decode options CAN FD (851-3191), ENET bus (878-7629); Manchester bus (878-7623), NRZ bus (878-7632), CAN LIN FlexRay package (878-7635), CAN (878-7639), LIN (878-7648), FlexRay (878-7641), SENT bus (878-7645), 12C SPI UART RS232 package (878-7654), 12C bus (878-7651), SPI bus (878-7663), UART RS232 bus (878-7679), AudioBus (878-7682), DigRF 3G bus (878-7689), DigRF V4 bus (878-7698), D-PHY bus (878-7695), ARINC 429 bus symbol (878-7708), MIL-STD-1553 (878-7695), USB 2.0 bus (878-7718), USB 2.0 HSIC (878-7724), power analysis (878-7749), spectrum analysis (878-7746). ###Comes with passive probe (1 per channel), beginner's guide, antivirus software (trial version), Microsoft Windows Embedded Standard 7 P 64 bit license, commercial NIST traceable calibration with certificate, power cable # # # Teledyne LeCroy HD oscillosco8825
-
Category: Oscilloscope and accessoriesDescription: HDO4000 The HDO4000 model of high-definition oscilloscope provides precise measurement and fast debugging. They combine Teledyne LeCroy's HD4096 high-definition technology with long-term memory, compact exterior design, 12.1-inch WXGA multi touch display, and powerful debugging tools. The innovative rotating/tilting foot allows for easy access to four different viewing positions, achieving optimal flexibility during use. Teledyne LeCroy HD4096 high-definition technology with 12 bit ADC resolution and multilingual user interface. Intuitive and efficient touch screen interface (such as configuring channels, timing, and triggering operations). WaveScan advanced search and lookup (such as low waves and spikes). LabNotebook document and report generation (just press a button). History recording mode, waveform playback, spectrum analyzer mode. Note that the separately provided HDO4000 accessories include: passive probe PP026-1 or PP026-2 (922-5270 or 922-5273); Current probes CP030A (878-7604) and CP031A (878-7607); High voltage differential probes HVD3106-6M (878-7601), HVD3206-6M (918-6866); Active probe ZS1500 (878-7610); Active differential probes ZD500 (878-7613) and ZD1500 (878-7617); Trigger and decode options CAN FD (851-3191), ENET bus (878-7629); Manchester bus (878-7623), NRZ bus (878-7632), CAN LIN FlexRay package (878-7635), CAN (878-7639), LIN (878-7648), FlexRay (878-7641), SENT bus (878-7645), 12C SPI UART RS232 package (878-7654), 12C bus (878-7651), SPI bus (878-7663), UART RS232 bus (878-7679), AudioBus (878-7682), DigRF 3G bus (878-7689), DigRF V4 bus (878-7698), D-PHY bus (878-7695), ARINC 429 bus symbol (878-7708), MIL-STD-1553 (878-7695), USB 2.0 bus (878-7718), USB 2.0 HSIC (878-7724), power analysis (878-7749), spectrum analysis (878-7746). ###Comes with passive probe (1 per channel), beginner's guide, antivirus software (trial version), Microsoft Windows Embedded Standard 7 P 64 bit license, commercial NIST traceable calibration with certificate, power cable # # # Teledyne LeCroy HD oscillosco8051
-
Category: Oscilloscope and accessoriesDescription: HDO4054 500MHz, 4CH., 2.5 GS/s + FreeOptions6803
-
Category: Oscilloscope and accessoriesDescription: Teledyne LeCroy The passive differential probe pair DXC100A is a high-performance passive matched differential probe pair designed for use with differential amplifiers in the DA1800 series. The probe pair includes two height matched and a single probe, sharing a common compensation box so that the attenuation factor of both probes can be switched between 10x and 100x simultaneously. When used with DA1855A differential amplifiers (801-4852, 801-4861), the attenuation factor of the probe is automatically incorporated into the effective gain display, and the decimal point position is automatically incorporated into the voltage generator display. Although primarily designed for use with amplifiers, the DXC100A differential probe pair can still be used with any oscilloscope or plug-in device with a 1M Ω/15-26pF and one inch (25.4 mm) spacing between connectors. When used on differential amplifiers, the DXC100A compensation box can accurately adjust and match instantaneous response and optimize the system's common mode rejection ratio (CMRR). DC to 100MHz bandwidth, with DA1855A maximum input voltage: 500V optional 10 or 100 attenuation factor 1.2m cable length # # # Passive oscilloscope probe # # # Note that all products in this series are available for use with tools with permanent grounding wires.6472
-
Category: Oscilloscope and accessoriesDescription: Teledyne LeCroy The Teledyne LeCroy current probe can accurately and reliably measure AC, DC, and impulse pulse currents without disconnecting the circuit or inserting a shunt. This ability is based on the combination of Hall effect and transformer technology. Many current probes require external power supply devices or amplifiers to display waveforms on the oscilloscope screen. LeCroy current probe is powered by LeCroy ProBus ® Connector power supply, no additional hardware required. In addition to providing power, the ProBus connector also enables communication between the current probe and oscilloscope, automatically displaying the current waveform in amperes on the screen and correctly calculating the power recorded on the scale in watts. This integration also supports direct activation of demagnetization and auto zeroing functions from the oscilloscope by pressing a button. The applications of LeCroy current probes include the design and testing of switching power supply equipment, motor drives, electric vehicles, and uninterruptible power supply equipment. Rise time (typical) Minimum sensitivity 1mA/div (CPO30A and CPO31A), 10 mA/div (CP030 and CP031), 100 mA/div (CP150 and CP500) AC noise coupling AC, DC, grounding cable length 1.5m (CP030 and CP031), 2m (CP150), 6m (CP500) Weight 240g (CP030 and CP031), 500g (CP150), 630g (CP500) ProBus interface, only 1M Ω (AP-1M required for use with oscilloscopes with only 50 Ω input) Indoor operating temperature 0 ° C to 40 ° C Maximum relative humidity: 80% Maximum altitude: 2000m # # # Note that CP030 (801-4858) and CP031 (724-0911) are compatible with LeCroy X-Stream oscilloscopes running firmware versions 4.3.1.1 or higher. Compared to CPO30A (878-7604) and CPO31A (878-7607) with a minimum sensitivity of 1mA/div, their minimum sensitivity is 10mA/div. The maximum wire size for these four models is 5mm od. The maximum sensitivity of CP150 (801-4855) and CP500 (724-0918) is 100mA/div, and the maximum wire size is 20mm od. The Teledyne LeCroy current probe is design2171
-
Category: Oscilloscope and accessoriesDescription: Teledyne LeCroy ZS The Teledyne LeCroy ZS series of high impedance active probes provides easy-to-use probes with high impedance and a wide range of probe tips and grounding attachments to handle a wide range of detection scenarios. A high 1 M Ω input resistance and a low 0.9 pF (0.6 pF when using ZS4000) input capacitance mean that these probes perform exceptionally well at all frequencies. The ZS series probes provide full system bandwidth for all Teledyne LeCroy oscilloscopes with bandwidths of 4 GHz and below. The combination of small size and a wide range of standard series cutting-edge accessories makes it easy to detect challenging situations and test points with spatial separation. High signal fidelity, up to 4 GHz bandwidth, low circuit load - high input impedance and low capacitance can be selected from 4 GHz, 2.5 GHz, and 1 GHz models. 1 M Ω input resistance 0.6 pF (4 GHz) and 0.9 pF input capacitance ± 8 V input dynamic range, ± 12 V bias range. Integrated oscilloscope (ProBus interface, used for control from the oscilloscope front panel) includes various tips and grounding probes5154
-
Category: Oscilloscope and accessoriesDescription: Teledyne LeCroy ZS The Teledyne LeCroy ZS series of high impedance active probes provides easy-to-use probes with high impedance and a wide range of probe tips and grounding attachments to handle a wide range of detection scenarios. A high 1 M Ω input resistance and a low 0.9 pF (0.6 pF when using ZS4000) input capacitance mean that these probes perform exceptionally well at all frequencies. The ZS series probes provide full system bandwidth for all Teledyne LeCroy oscilloscopes with bandwidths of 4 GHz and below. The combination of small size and a wide range of standard series cutting-edge accessories makes it easy to detect challenging situations and test points with spatial separation. High signal fidelity, up to 4 GHz bandwidth, low circuit load - high input impedance and low capacitance can be selected from 4 GHz, 2.5 GHz, and 1 GHz models. 1 M Ω input resistance 0.6 pF (4 GHz) and 0.9 pF input capacitance ± 8 V input dynamic range, ± 12 V bias range. Integrated oscilloscope (ProBus interface, used for control from the oscilloscope front panel) includes various tips and grounding probes1291